KPM30

CATEGORY: THERMOREGULATION SYSTEM

Regulation module for heating and/or cooling systems. With built-in display.   Description The KPM30 and KPM31 regulation unit derives from Giacomini's extensive experience in the field of thermoregulation of heating and coolingsystems. The KPM30 regulation unit is a device designed to be used in Giacomini radiant heating and/or cooling systems in combination with busthermoregulation components and other communicating devices withcompatible protocols. The KPM30 module is equipped with a d...

Regulation module for heating and/or cooling systems. With built-in display.
 
Description
The KPM30 and KPM31 regulation unit derives from Giacomini's extensive experience in the field of thermoregulation of heating and cooling
systems. The KPM30 regulation unit is a device designed to be used in Giacomini radiant heating and/or cooling systems in combination with bus
thermoregulation components and other communicating devices withcompatible protocols. The KPM30 module is equipped with a display and six
multifunctional keys; this allows programming of the system parameters via a guided menu and the subsequent monitoring of the system by the user.
The KPM30 module allows for quick connection to the ambient thermostats K492B, K495B and K495L and to the KPM35 expansion boards.
In addition, the operation of the circulator and the activation of the mixing valve servo-control is managed automatically.
The KPM31 version has the same characteristics as the KPM30 but without the display, therefore it must be installed in combination with the remote
display KD201 (which is an optional accessory for the KPM30 model). Thanks to the plug-in terminals and the design compliant with the DIN standard, it
can be installed in accessible electrical panels.
 
Technical data
• Operating conditions: -10÷60 °C, 90 % R.H. non-condensing
• Storage and transportation conditions: -20÷70 °C, 90 % R.H. non-condensing
• Protection degree: IP40 front panel only
• Environmental pollution: 2
• Class according to the protection against electric shock: to be integrated on
Class I and/or II equipment
• Period of electrical stresses of the insulating parts: long
• Type of action: 1 C
• Type of disconnection or microinterruption: microinterruption
• Heat and fire resistance class: Class D (UL94–V0)
• Immunity against voltage surges: Class II
• Ageing characteristics (hours of operation): 80.000
• No. of automatic operating cycles: 100.000 (EN 60730-1); 30.000 (UL 873)
• Software class and structure: Class A
• Surge immunity class: Class III (CEI EN 61000-4-5)
The device is not intended to be hand-held.
 
 
 